Sale!

Kidde-Fenwal05-296623-751Ignition Control Board Direct Spark 24 VAC CSA

Original price was: $172.40.Current price is: $43.10.

SKU: 4373385403 Categories: , ,

Description

Fenwal 05-296623-751 Ignition Control Direct Spk 24 VAC CSA, Ignition Time 4.7 Seconds.
Direct Replacement This is no longer available, you will be provided with suitable factory replacement. Used on the Heatilator gas log as well as, several other appliances. GC300 series

Technical Specification

SPECIFICATIONS

Size With Enclosure: 5.69 x 3.94 x 1.87 in (144.4 x 99.9 x 47.5 mm) Without Enclosure: 5.50 x 3.75 x 2.00 in (139.7 x 95.3 x 50.8 mm)
Weight (with enclosure) Approximately 7.0 oz (200 g)
Input Voltage 24 VAC %/-15%, 50/60 Hz
Input Current Drain 90 mA RMS maximum (270 mA peak) while sparking. Does not include valve power.
Valve Relay Contact Rating 1.0 A (Inrush 2.5 A maximum)
Combustion Blower Relay 8A @ 250 VAC (1/4 HP)
Prepurge None, 15 or 30 seconds depending on model. Without prepurge there is less than 1.0 second delay before single try for ignition.
Ambient Temperature Limits -40 def. F and 힞 deg. F ( -40 and deg. C)
Moisture Resistance Each module is conformal coated to operate to 90% R.H. However, care must be taken to protect module from direct exposure to water.
Tries for Ignition Available in one- or three-try versions.
Trial-for-Ignition Periods 3.3, 4.7, 6.8, 10.0, or 12.0 seconds, depending on model.
Flame Failure Retry When loss of flame occurs after the initial try for ignition. the control system provides one retry on single-try models and two retries on three-try models
Flame Current 5 microamp minimum
Flame Failure Response Time Within 0.8 second
Spark Rate 60 sparks per second (synchronous)
Types of Gas Natural. LP, or manufactured
Connections 1/4 inch spade type (3/16 inch for V1)
Sensor Single spark and sense using high voltage spark electrode as the sensing element or remote sensing using a separate sensing element.
Enclosure (Optional) Gray Noryl fire retardant plastic

CONTROL CONFIGURATION

Method of Flame Sensing

Single Spark and Sense

Tries for Ignition

Single Try for Ignition

Mounting/Enclosure Configuration

Fire Retardant Plastic Enclosure

Prepurge Period

No Prepurge

Blower Relay

No Relay

Trial-For-Ignition (TFI) Time

4.7 Seconds